TempTracker mod+ Hybrid Installation and Operation Manual 37
HTC# 059105-00D

DAY/NIGHTSCHEDULE
SetTime **:**
DaySchedule 6:00a
NightSchedule8:00p
BACKSAVE
--DAYSCHEDULE--
6:00Am
BACKSAVE

(Available when "Shutdown or Tstat" is selected from the Shutdown/Tstat/
Setback Startup menu option only)
Button: MENU/<System Settings>/<More Settings>/Day/Night Schedule
The TempTracker mod+ Hybrid has two levels of heat. The Day (Normal) level is used
when a building is occupied and people are active.
The Night (Setback) level is used when a building is not occupied, or when people are
sleeping. This setting reduces the calculated temperature by the Setback setting. See
"Setback" on page 33. If the Day calculated water temperature was 150˚F and the Setback
was 20˚F, the Night Schedule will run at (150˚F - 20˚F) = 130˚F.
If the Boost feature is being used, it uses the Day Schedule as the Boost ending point. See "Boost Mode" on page 26. That
is, if the Day Schedule is set to start at 6:00AM, the Boost will start 30 minutes prior to the Day setting at 5:30AM. The
TempTracker mod+ Hybrid will then raise the calculated water temperature by the Setback amount. Using the previous example,
at 5:30AM the TempTracker mod+ Hybrid will raise the calculated water to 170˚F = (150˚F + 20˚F) until 6:00AM.

Button: MENU/<System Settings>/<More Settings>/Set Time
Adjust the time by selecting Set Time from the menu and then scrolling through the hours
then select Save. If the hours are to be set to PM, scroll through the AM hours to reach the
PM hours. Then, scroll through the minutes then select Save.
-----SETTIME-----
7:35Pm
BACKSAVE

Remember that the battery is the backup for the Time. If no power is supplied to the TempTracker mod+ Hybrid
and there was no battery or the battery had no power, time values will be lost and will need to be reset.

Button: MENU/<Maintenance>
The Maintenance menu gives access to sensor and modulating output trimming. In addition,
you'll have access to view the Startup conguration settings.

To be able to change the TempTracker mod+ Hybrid settings the Program/Run
Switch must be set to Program. The switch is located under the Enclosure Wiring
Cover for security. The Enclosure Wiring Cover can be secured using a lock.
-----MAINTENANCE----
SystemTrim +0
o
F
OutdoorTrim 0
o
F
<OutputTrim>
<Configuration>
BACKSAVE
SYSTEM
A
B
C
D
1
2
RUNPROGRAM
DO NOT APPLY ANY VOLTAGE
TO INPUT TERMINALS
3
4
5
6
7
8
9
10
11
12
13
15
14
17
16
18
20
19
21
24
23
29
25
27
26
28
32
30
31
L
N
-
+
+
T
T
O
O
RS-485
mA
GND
VLT
SYS
A
B
C
D
PWR
CUR / VLT
A
-
+
+
mA
GND
VLT
-
+
+
mA
GND
VLT
+
+
mA
22
-
GND
VLT
+
mA
TEMP
OUTDOOR
O
O
TEMP
SYSTEM
EXTENSION
MODULE
CUR / VLT
B
CUR / VLT
C
CUR / VLT
D
PROVE
/DHW
SHUTDOWN
/SETBACK
FOR ALL CIRCUITS
120VAC, 6A RESISTIVE
OUTPUT RATINGS:
1A PILOT DUTY, 15A TOTAL
115VAC 60Hz , 30VA MAX
INPUT RATINGS:
USE COPPER WIRE,
CLASS 1 WIRE ONLY.
CAUTION: RISK OF ELECTRIC SHOCK
More than one disconnect switch may be required
to de-energize the equipment before servicing.
ENCLOSED
ENERGY
MANAGEMENT
EQUIPMENT
99RA
/TSTAT
HYBRID

Adjustablefrom-5F°/-3C°to+5F°/+3C° Default:0°F
Button: MENU/<Maintenance>/System Trim
Button: MENU/<Maintenance>/Outdoor Trim
The Raypak thermistor type sensors are very accurate, and normally require no calibration.
Sometimes it may be desirable to make small adjustments to the displayed value for either
the Outdoor temperature (OD) or the System temperature (SYS). The Trim setting is used to
adjust the displayed value.
Do not use the Trim setting to make the Outdoor temperature sensor match that reported on
the radio or TV. Outdoor temperature can vary widely over a broadcast range. Only trim
the outdoor sensor based on an accurate thermometer reading taken where the sensor is
located.
SYSTEMSENSORTRIM
+0
o
F
[ ]
BACKSAVE
OUTDOORSENSORTRIM
+0
o
F
[ ]
BACKSAVE