If the PRS fault code is displayed, it indicates that
there is insufficient water flow through the heater.
Make sure the pool filter and pump strainer are clean
before calling a service representative.
DIAGNOSTICS
The digital thermostat models are equipped with on-
board diagnostic controls. If there is a safety fault, a
fault code will be displayed along with a service
indication.
READING A FAULT
The word “SERVICE” will flash on and off if the PC
board detects a known fault. The fault will be dis-
played in three big letters on the lower left of the dis-
play.
Service Will
Flash
3 Letter
Fault Code
See table
for fault
definition
STATUS CODES
Display Definition
CFH Call for heat
CLK Time clock
EOL End of line test (Factory Use Only)
LON Lo NOx Unit
OFF Off mode
PRO Propane gas configured
REM Remote control activated
SPK Spark
SPR Spare fault code indicator
FAULT CODES
Display Definition
BD1 Board failure
EEP Microprocessor error
FAN Blower pressure failure
FFL Flame sensing when pilot and gas
valves are closed
GVC Gas valve closed
GVO Gas valve open
HL1 High limit switch #1 open
HL2 High limit switch #2 open
IGN Ignition failure
ILO Ignition lockout - Propane units only
PRS Water pressure switch open
ROL Heat roll-out safety switch open
SNS Sensor failure, Water temp. below 36°F
or above 110°F
VNT Vent switch open - This is jumped from
the factory.
PROGRAM MODES
Display Definition
CCC Celsius setting
F/C Change from Fahrenheit to Celsius
FFF Fahrenheit setting
RES Reset defaults
SET Set point max adjustment
NOTE: The LCD temperature display may not agree with the temperature reading of your pool or spa ther-
mometer. The heater reads the water temperature at the inlet. Due to the circulation characteristics of any pool
o
r spa, the water temperature at the inlet to the heater may differ from that observed at a given location in the
pool or spa.
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 59 60

Comments to this Manuals

No comments