Raypak Power Vent D2 Specifications

Browse online or download Specifications for Water heaters & boilers Raypak Power Vent D2. Raypak Power Vent D2 Product specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 102
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
2OO7
hydron cs
design supply support
REV-2
10 Industrial Parkway Woburn, MA 01801 Tel. 781-721-0303 Fax 781-721-9119
www.CapcoSupply.com
Page view 0
1 2 3 4 5 6 ... 101 102

Summary of Contents

Page 1 - supply support

2OO7hydron csdesign supply supportREV-210 Industrial Parkway Woburn, MA 01801 Tel. 781-721-0303 Fax 781-721-9119www.CapcoSupply.

Page 2 - 2007 STOCK CARD

BUDERUSGB-142WALL HUNGGASSUPPLYBUDERUSGB-142WALL HUNGGASSUPPLYBUDERUSGB-142WALL HUNGGASSUPPLYCut Here,Then sweat tees out of ball valves781-721-0303

Page 5

CONVERSIONSCONVERSION FACTORS1 U.S. Gallon Equals 231 Cubic Inches 1 Cubic Foot Equals 7.48 U.S. Gallons0.1337Cubic Feet 0.0283 Cubic M

Page 6 - GB142 With AM10, ZVC Control

Single Boiler Control Controlling a single boiler using a building monitoring system or external controller that provides a modulating 0-10Vdc or 0-2

Page 7 - INSTRUCTIONS

Scenario 2: Controlling 2 boilers using a 0-10Vdc or 0-20mA output from a building monitoring system or external controller: Solution: 2 GB142 boilers

Page 8 - 09/06/2006

Multiple Boiler Control 3 Boilers Scenario 1: Tekmar 265 or Tekmar tN4 w/ 3 EM10 modules and no DHW Tekmar (See Tekmar Documentation for details) Pipi

Page 9

RWCL7148FS-2S-1RCB-2B-1 RLX-1 LX-2GL-2C-1 C-2L-19NDo not apply power21 345Com Boil Boil Out UnOSup Ret Sw12 13 16 17181920 2221 23C.A. /AlarmLP11011Pr

Page 10 - Manifold cut

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 11

COMRW24VACTTNH34N/O4N/C6N/C6N/O5SR5011 ZONE SWITCHING RELAY120 VACINPUTPOWERT STAT120V (ac)Class IITransformer 24V (ac)CNLRTo Mix Demand781-721-0303

Page 12

Back of ControlBoiler OperationCom Sup Sys Com Boil Out Com HeatDemRetBoilerOff-Enable On-ControlRMBPumpNHS1S1Outdoor Sensor110 Volt Power SupplyCorde

Page 13

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 14 - 5A 5A 5A 5A 5A5A

COMRW24VACTTNH34N/O4N/C6N/C6N/O51 ZONE SWITCHING RELAY120 VACINPUTT STATSR501POWER781-272-0020 FAX 781-272-0514 WWW.CAPCOSUPPLY.COMTHIS I

Page 15 - 120V (ac)

2007 STOCK CARDBOILERS HEATING SPECIALTIES OIL TANKSBuderus Clic Hangers Highland Oil TanksLochinvar Garber Oil Filters RothRayPak Harvey ChemicalsVie

Page 16 - SR 501 Wiring Match Up

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 17

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 18 - To System

VALVE 1ZONE 31 2 3 4ZONE 11 2 3 4ZONE 21 2 3 4 T TZONE 3E SOOMNCCNFACTORYINSTALLEDTRANSFORMERPOWER INFUSE3ARESETT TZONE 1

Page 19

BUDERUS “ QUICK HEADER” JUNCTION MANIFOLDPanel RadiatorsTile Floor RadiantWood Floor RadiantP-2 P-3 P-4SX40VP-1781-721-0303 FAX 781-721-9119

Page 20 - 7.5A7.5A

131415161718DonotapplypowerComComUnOSwBoilOutIndr10A10A9101112DHWBoilerPmp/Vlv10A12346875BoilerDemandDemandDHWPowerLNBoilP1N260781-272-0020FAX781-272-

Page 21 - 2 Stage / Heat - Cool

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 22 - 12345 13 14

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 23 - P-2 P-3 P-4

781-272-0020 FAX 781-272-0514 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUSTBE FIELD VER

Page 24

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 25 - ENERGY SUPPLY, INC

TurboMax tank with Buderus GB142 boiler being used in conjunction with the prepiped manifold and the Buderus DHW sensor in the turbomax tank. To achie

Page 26

Application Drawings Buderus GB 142 Boiler with AM10, Taco ZVC, and DHW as a Setpoint……….…………….…1 GB 142 Boiler with AM10, Taco SR, and DHW as a Set

Page 27

SX40VSYSTEM FILLDHW Hot OutletDHW Cold InletRecirc pump Typical Piping781-721-0303 FAX 781-721-9119 WWW

Page 28

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 29 - 02/13/2007

L1GNMPRESSURESWITCHBKWHGNRDBK1GNYEBK2BK3BK4BK5BK6414141IN-FORCER PAI-1G, PAI-2GFAN IN CAN CAS-3L1 NMT1 T2T3G120VAC41BKWHGNRDBK1GNYEBK2BK3BK4BK5120V

Page 30

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 31

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 32

X2123456789COMRW24VACTTNH34N/O4N/C6N/C6N/O51 ZONE SWITCHING RELAY120 VACINPUTT STATJUMPERSR501POWERDHW Aquastat120V (ac)NL115 Volt ConnectionDHW Pump7

Page 33 - TJERLUND

Pumping Away1The Point of No Pressure Change The point where the expansion tank connects to a closed hydronic system is called the Point of No Pressur

Page 34 - VIE MANN

How to Select a Pump Follow This Path to Select the Proper Pump: 1. Calculate BTUh – BTUh is the heat output capability of the heat source over time.a

Page 35

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 36 - Pumping Away

½” Black PlugDouble Tapped Bushing3/8" Compression X ½” NPT male fitting½” Black Iron Pipe chase3/8" Flare x MNPT Ftg’sFiromatic Oil Valves

Page 37

Viessmann Vitotronic 200 with Taco SR & ZVC Controls…….……………………...…………….26 Combustion Air Controls………………………………………………………………...27 Viessmann Double

Page 38 - MCB 4/12/05

Multiple Roth Oil Tank Piping Schematic*781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS A

Page 39 - 3/8" Flare x MNPT Ftg’s

VIEGA NA 877-VIEGA-NA IM-SNO-09/04SYSTEM DESIGN - CHAPTER 33.6 Water/ Glycol Mixture:Selecting the percentage of GlycolMixture:Freeze protection i

Page 40

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 41 - SYSTEM DESIGN - CHAPTER 3

SX40VMExspansion Tank Glycol Feed TankSnowmelt Manifold781-721-0303 FAX 781-781-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. A

Page 42

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 43 - Basic Snowmelt/Axiom

27364581This is a depiction of a 115 volt circuit.115 volt or 230Volt power supply is possible. For 230 Volt, the nuetral leg would be hot and all of

Page 44

781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE FIELD VE

Page 45

Chiller781-721-0303 FAX 781-721-9119 WWW.CAPCOSUPPLY.COMTHIS IS ONLY A CONCEPT DRAWING. ALL CONDITIONS AND NECESSARY COMPONENTS MUST BE F

Page 46 - Unico Control Box

Wiring Instructions for adapting the S8610U Honeywell Ignition Control to any boilerWARNINGHoneywell MPLS., MN 55422Explosion Hazard.Can Cause Seriou

Page 47

Wiring Instructions for adapting the S8610U Honeywell Ignition Control to any boilerWARNINGHoneywell MPLS., MN 55422Explosion Hazard.Can Cause Seriou

Page 48 - SINGLE ROD SYSTEM

Product Specifications Continued Tekmar 4 Way Mixing Valve Sizing…………………………………………………72-73 Turbomax Product Specifications………………………………………………………..74 V

Page 50

www.buderus.netQuick-FitTMModular Piping SystemSimplifies and Speeds Any Boiler Installation Quick-Mix Mixing Station for Radiant Flooring Applicati

Page 51 - Quick-Fit

Quick-Mix StationThe Quick-Mix Station is a fully assembled radiant heat mixing station that conveniently combines a motorized mixing valve, circulato

Page 54

Hydro Separator series 548CALEFFI01076/03 NAcert. n° 0003ISO 9001FunctionThis device consists of several different functional components,each of which

Page 55 - Hydro Separator

Technical characteristics of insulation(supplied on flanged models only)Internal part- Material: rigid closed cell expanded polyurethane foam- Thickne

Page 56 - Gprimary < Gsecondary

Constructional detailsIsolating the air vent valveIn flanged separators, the air vent isisolated manually, using a shut-off ballvalve. In threaded sep

Page 57 - THREADED FLANGED

SELECTIONS Ð SNOW MELTFlatPlate heat exchangers are very cost effective in Snow Melt applications and provide high output, fast response and

Page 58 - SELECTIONS Ð SNOW MELT

SELECTIONS – SWIMMING POOLS & SPAS1. Typical Design Conditions: 180˚F Boiler Water to HX, 80˚F Pool Water.2. For 160˚F Boiler W ater, multiply pro

Page 59 - WIMMING POOLS & SPAS

DHW TTNH34N/O4N/C6N/C6N/O51 ZONE SWITCHING RELAYT STATJUMPERSR501POWERCirculatorLine voltage120 VoltsWhen piped as a zone781-721-0303 FAX 781-

Page 60

SELECTIONS – SWIMMING POOLS & SPASStep 3 Select the Heat Exchanger and BoilerOutput RequiredFrom the Selection table, based on thePool Capacity

Page 61 - SELECTIONS – RADIANT FLOOR

SELECTIONS – RADIANT FLOORConnected to Boiler: Radiant Floor Radiant Floor Radiant Floor180˚F Supply, 150˚F Return 80˚F return, 100˚F supply 100˚F ret

Page 62 - UPS 15-58FC/FRC SUPERBRUTE

TECHNICAL DATA GRUNDFOS SERIES UPUPS 15-58FC/FRC SUPERBRUTEFlow range: 0 - 17.5 U.S. GPMHead range: 0 - 19 FEETMotors: 2 Pole, Single PhaseMaximum fl

Page 63 - UPS 26-99FC/BFC SUPERBRUTE

GENERAL DATA GRUNDFOS SERIES UPUPS 26-99FC/BFC SUPERBRUTEFlow range: 0 - 34 U.S. GPMHead range: 0 - 30 FEETMotors: 2 Pole, Single PhaseMaximum fluid

Page 64 - UPS 43-44FC/BFC SUPERBRUTE

GENERAL DATA GRUNDFOS SERIES UPUPS 43-44FC/BFC SUPERBRUTEFlow range: 0 - 64 U.S. GPMHead range: 0 - 14 FEETMotors: 2 Pole, Single PhaseMaximum fluid

Page 65 - HARVEY HEAT -100 ANTIFREEZE

Nontoxic / NoncorrodingHARVEY HEAT -100 ANTIFREEZEWARNING: KEEP OUT OF THE REACH OF CHILDREN. DO NOT TAKE INTERNALLY.For Emergency First Aid Help Cal

Page 68 - 60 Hz Performance Field

Performance Field Information60 Hz Performance Field60 Hz Performance Field63

Page 69 - Hydronic Accessories

Taco iSeries Mixing Valves are a breakthrough in precision, cost effective temperature control for heatingsystems. Available in 2-way mixing or 3-way

Page 70 - TACO, Inc

DHW Factory Installed JumperRC 10 /20Outdoor sensorT T ConnectionDHW SensorSafetyLimitOrange Blue Lt Green Lt Gray RedLow VoltageEVFWWAFARC1 2White1

Page 71 - Installed

R-seireSiR-seireSiOutdoorSensorSupplySensorOutdoorSensorSupplySensorBoiler Sensor Boiler SensorBCABCABoilerSensorSupplySensorOutdoorSensoriSeries-RMul

Page 72 - -ANIFOLD2EADY

iSeries-RBCABCASupplySensorNPZCHX1ZRX2ZONE1 ZONE2 ZONE3ZONE1 ZONE2 ZONE3FUSE 1 AMP24 VACPOWERTHREE ZONE SWITCHING RELAYWITH OPTIONAL PRIORITYSR 50324

Page 73 - 2ADIANT-IXING"LOCK

4HE4ACO2ADIANT-IXING"LOCKREPRESENTSABREAKTHROUGHINTHEDESIGNCONTROLANDINSTALLATIONOFRADIANTSYSTEMS4HEPATENTPENDINGDESIGNCO

Page 74 - Back of Control

3UBMITTAL$ATA3UPERSEDES.EW%FFECTIVE!PPLICATION4HE4ACO2ADIANT-IXING"LOCK2-"ISACOMPLETEINJECTIONMIXINGSYS

Page 75 - - Data Brochure

Radiant Mixing Block Connected to Zone Valve Control with System Pump Wired off the RMBRadiant Mixing Block Connected to 2 EXP Switching Relays with D

Page 76 - Technical Data

© 2005 D 710 - 05/05D 71005/05- Data Brochure3-Way Mixing Valves 710 - 714The 3-Way Brass Mixing Valves 710, 711, 712, 713, and 714 are used to

Page 77

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fa

Page 78

© 2005 D 720 - 05/05D 72005/05- Data Brochure4-Way Mixing Valves 720 - 724The 4-Way Brass Mixing Valves 720, 721, 722, 723, and 724 are used to

Page 79 - NDIRECT WATER HEATERS

tekmar Control Systems Ltd., Canadatekmar Control Systems, Inc., U.S.A.Head Office: 5100 Silver Star RoadVernon, B.C. Canada V1B 3K4(250) 545-7749 Fa

Page 80 - Pextron Tubing Data

TURBOMAX INDIRECT WATER HEATERSTURBOMAX®109Domestic hot water produced per hour in U.S. gallons†Net First hour ContinuousBTUH kW 110°F 140°F 180°F 110

Page 81 - Specifications

BUDERUSGB-142WALL HUNGGASSUPPLYBUDERUSGB-142WALL HUNGGASSUPPLYCALEFFITo space heatingDHW TankMTo Mixed ZonesPiping Example for (2) GB-142's and D

Page 82 - Product Instructions

Pressure Drop ChartPextron Tubing DataAP-PDROP-1006 Pextron Tubing Data TableNominal Size (in.) Outside Diameter (in.) Inside Diameter (in.) Water C

Page 83 - Diverting Valve

Pextron TubingSpecificationsVIEGA NORTH AMERICA • Building Tomorrow’s Plumbing & Heating Technology ... Today3 Alfred Circle • Bedford, MA 01730 •

Page 84

VIEGA • One Company... One Partner... Delivering System Solutions.301 N. Main, Floor 9 • Wichita, KS 67202 • Ph: 877-Viega-NA • Fax: 316-425-7618 • E-

Page 85

Diverting ValveProduct InstructionsVIEGA NORTH AMERICA • Building Tomorrow’s Plumbing & Heating Technology ... Today3 Alfred Circle • Bedford, MA

Page 86

Diverting ValveProduct InstructionsVIEGA NORTH AMERICA • Building Tomorrow’s Plumbing & Heating Technology ... Today3 Alfred Circle • Bedford, MA

Page 87 - BUDERUS

4.2 Sizing the 3-Way Mixing Valve4.2 Sizing the 3-Way Mixing ValveThe selection of the size of the mixing valvecan be done using the above diagram. Th

Page 88 - AM10 QUICK SET UP (CONT”D)

3.2 Sizing the 4-Way Mixing Valve3.2 Sizing the 4-Way Mixing ValveThe selection of the size of the mixing valvecan be done using the above diagram. Th

Page 89 - Quick Set Up Sheet

BUDERUS AM-10 QUICK REFERENCE SHEETWiring: There are three sets of terminals along the bottom of the control. THE BOTTOM OF THE CONTROL WILL END UP UP

Page 90 - This is for SETPOINT USE ONLY

The Basepoint adjustment is adjustable and is simply the minimum supply temperature that you want the boiler to shoot for whenever the boiler has a ca

Page 91 - Page 3 Lochinvar Quick Set Up

The Knight BoilerQuick Set Up SheetQuick Set Up Instructions for entering settings for “INSTALLERS ONLY”.Press Once to Enter “programming”...boiler wi

Page 92 - Lochinvar Quick Set Up Sheet

DHW 1 2White1 2RCRed1 2FABlueT TAM 10 ModuleOutdoor sensorLine voltage120 VoltsDHW AquastatSR 503 EXPPOWERZONE 1ZONE 2ZONE 3INSTRUCTIONSThis wiring di

Page 93 - Radiant Mixing Block

Page 2 of Lochinvar Quick Set Up SheetFirst, set the Time and Date In the General Menu or “A”Press and Release the Enter Button when the Caret > is

Page 94

Page 3 Lochinvar Quick Set UpFor DHW ProgrammingWith Installer Code programmed in, while still in Menu...Go to “E”E-1 is the DHW Target Temperature fo

Page 95 - 02/23/2007

Lochinvar Quick Set Up SheetF-7 Shift Reset Curve, Leave at Factory setting or “No Shift”F-8 Boost Temperature, LeaveF-9 Boost Time, LeavePress Menu

Page 96

Radiant Mixing Block Quick Set UpViewMixI07FITEMDemRadiant Mixing BlockSUPMENUTMPATENT PENDINGRMB-1For use as a Boiler Control or Radiant Heating Cont

Page 97

4.) Push and release the Item button: The next Item to appear will be the MIX MINIMUM will appear. This is the temperature you will set the supply wat

Page 98

5.) Units of Temperature: Set to Fahrenheit or Celcius.Dip Switches 1.) Behind the front panel where programming is done, if you remove the display, y

Page 99

Dip Switches: When to flip them, what they do and how they affect things. 1.) Advanced: This is the position the dip switch should be in

Page 100

(Continued from previous page)The Boiler contact is controlled by several things. The boiler contact wil make whenever there is both a mixed demand (t

Page 101

Terminal UnitMIX MAXMIX MINMIX DSGNHIGH MASS RADIANT1High Mass Radiant1Fancoil3Fin-Tube Convector4Low Mass Radiant2Radiator5Baseboard120 F140FOff145 F

Page 102 - CONVERSIONS

AdjustMIX I40F11.) Press Item button again and Boiler Minimum will appearThis is the minimum temperature the boiler will be allowed to be when a mixed