Catalog No.: 6000.342D Effective: 9-01-09 Replaces: 6-22-08
Job:
Engineer:
Contractor:
Prepared By: Date:
Model: Indoor/Outdoor: MBTUH Input:
Sealed Combustion Chamber
100% Factory Fire Tested
Efficiency: 85%
Minimum Non-condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-year Thermal Shock Warranty
Limited Five-year Heat Exchanger Warranty
Full Safety Diagnostics with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-assisted
Non-ferrous Bypass
Patented Burner Security Blanket
Heat Exchanger
Brass Headers
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Cupro Nickel Finned Tubing
ASME Steel Tube Sheet
Silicone High Temp O-Rings
125 PSIG ASME Pressure Relief Valve
Temperature and Pressure Gauge
Water Connections
Left – Standard
Right – Option A-6
Bronze Pump, 120V, 60Hz
Non-ferrous Pool Bypass
Controls
120V, 60Hz, 1 Power Supply
120/24V 60Hz Transformer
100% Shut-off/Lockout
Hot Surface Ignition Systems (2)
Remote Flame Sensors (2)
High Limit Control, Auto Reset
On/Off Power Switch
Manual Shut-off, Front-mounted
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches
Economaster Pump Time Delay
Poolstat
Diagnostic Panel with LCD Display
2 Lines, 20 Characters
Gas Train
Combination Valves
On/Off Firing
Low Gas Pressure Switch, Manual
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.56/
CSA 4.7 (P models)
Design Certified ANSI Z21.10.3/
CSA 4.3 (WHP models)
Burner
Ultra-low NOx:
Less than 20 PPM
Construction
Indoor/Outdoor Construction
Enclosed Front Controls
Venting
Vent Location
Top – Standard
Rear – Option D-14
Vent Termination Cap
Outdoor – Option D-11
Indoor, Horizontal –
Option D-15
Indoor, Vertical (by others)
Combustion Air
In-Line Filter Kit (TruSeal
only) – Option D-17
Air Intake Elbow –
Option D-16
Options
C-6 Ignition Module, Manual Reset
D-21 TruSeal™ Direct Vent
Right Side
Left Side (Model 1802B
Only)
F-10 Low Water Cut-off, Remote
Probe
P-__ Cold Water Run System
(See Page 3)
S-2 Dual High Gas Pressure
Switches, Manual Reset
X-1 SureRack Kit
X-2 SureRack Kit Above Grade
Add-on (used with X-1)
Y-241 Temperature Controller,
1-4 Stages
Regulatory Agency Requirements
G-1 CSD-1
Hi Delta
®
- Type P
Commercial Pool Heaters
Models 1802B-2342B
Standard “H” B
yp
ass Shown
Patent No. 7,044,124
Page view 0
1 2 3

Summary of Contents

Page 1 - - Type P

Catalog No.: 6000.342D Effective: 9-01-09 Replaces: 6-22-08 Job: Engineer: Contractor: Prepared By: Date:

Page 2 - Hi Delta – Type P

Hi Delta – Type P Models 1802B-2342B Model ** Requires separate circuit breaker Model MBTUH Amp Draw Input Output A Width K

Page 3

Hi Delta – Type P Models 1532B-2342B (Cold Water Run Option) Model *Separate 120 VAC or 240 VAC 1Ø power required for Cold Water Run op